report_el-hj212.go 8.0 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192
  1. package iotElProtocol
  2. import (
  3. "IotAdmin/common/global"
  4. "IotAdmin/core/logger"
  5. "IotAdmin/core/sdk"
  6. "IotAdmin/core/tools/utils"
  7. iotInterface "IotAdmin/iot/interface"
  8. iotMap "IotAdmin/iot/map"
  9. iotProtocol "IotAdmin/iot/protocol"
  10. iotReportService "IotAdmin/iot/service/reportService"
  11. iotStruct "IotAdmin/iot/struct"
  12. "IotAdmin/iot/struct/electric"
  13. "encoding/json"
  14. "fmt"
  15. "strconv"
  16. "time"
  17. )
  18. type elHj212 struct {
  19. }
  20. func NewElHj212ReportHandler() iotProtocol.ReportHandler {
  21. return &elHj212{}
  22. }
  23. func (*elHj212) Adapter(data *iotStruct.CollectData) {
  24. cfg := data.SlaveConfig
  25. // 获取电表计算参数
  26. calc, today, err := getMeterElectricCalc(cfg)
  27. if err != nil {
  28. data.Logger.Errorf("[%s]获取计算参数失败: %s", cfg.No, err.Error())
  29. return
  30. }
  31. mData := calc.GetMeterData()
  32. elMeter := mData.(electric.MeterElectric)
  33. // 计算电表数据
  34. data.Logger.Debugf("[%d]计算前: [%v]", today, calc)
  35. elMeter.Time = today
  36. elMeter.CalcMeterData(data)
  37. data.Logger.Debugf("[%d]计算后: [%v]", today, calc)
  38. // 更新电表计算参数
  39. calc.SetMeterData(elMeter)
  40. updateMeterCalc(elMeter, &calc)
  41. }
  42. func (*elHj212) Report(data *iotStruct.CollectData, config *iotStruct.ReportConfig) (reportStr *string) {
  43. if str, ok := packHj212(data, config); ok {
  44. reportStr = &str
  45. if receive, err := iotReportService.UpToServer(config.Host, str); err != nil {
  46. data.Logger.Errorf("[%s:%s]上报数据失败: [ %s ] %s", config.Host, str, err.Error())
  47. } else {
  48. data.Logger.Debugf("上报数据 SEND -> %s", str)
  49. data.Logger.Infof("上报数据 RECE <- %s", receive)
  50. }
  51. } else {
  52. data.Logger.Errorf("[-- %s --]打包数据失败 %v", data.SlaveConfig.No, data)
  53. }
  54. return
  55. }
  56. func getMeterElectricCalc(cfg *iotStruct.SlaveConfig) (calc iotInterface.MeterCalc, tms int, err error) {
  57. now := time.Now()
  58. today, _ := strconv.Atoi(now.Format("20060102"))
  59. tms = today
  60. if x, ok := iotMap.MapMeterCalc.Get(cfg.No); ok {
  61. calc = *x
  62. } else {
  63. calc = nil
  64. }
  65. if calc == nil {
  66. switch cfg.Protocol {
  67. case iotProtocol.MeterAdw300:
  68. calc, err = electric.NewMeterADW300(cfg.No, today, "", cfg.OtherConfig)
  69. if err != nil {
  70. err = fmt.Errorf("创建电表[%s]-[%s] 计算参数失败: %s", cfg.No, cfg.Protocol, err.Error())
  71. return
  72. }
  73. case iotProtocol.MeterPmc350b:
  74. calc, err = electric.NewMeterPMC350B(cfg.No, today, "", cfg.OtherConfig)
  75. if err != nil {
  76. err = fmt.Errorf("创建电表[%s]-[%s] 计算参数失败: %s", cfg.No, cfg.Protocol, err.Error())
  77. return
  78. }
  79. default:
  80. err = fmt.Errorf("不支持的协议: %s %s", cfg.No, cfg.Protocol)
  81. return
  82. }
  83. }
  84. return
  85. }
  86. func updateMeterCalc(elMeter electric.MeterElectric, calc *iotInterface.MeterCalc) {
  87. q := sdk.Runtime.GetMemoryQueue("")
  88. data, err := json.Marshal(elMeter)
  89. if err != nil {
  90. logger.Errorf("更新电表计算参数失败: %s", err.Error())
  91. return
  92. }
  93. mp := make(map[string]interface{})
  94. mp["data"] = string(data)
  95. mp["id"] = elMeter.Id
  96. mp["time"] = elMeter.Time
  97. message, err := sdk.Runtime.GetStreamMessage("", global.UpdateMeterCalc, mp)
  98. if err != nil {
  99. logger.Errorf("构建更新表计计算参数 message [%s]失败: %v", global.UpdateMeterCalc, err)
  100. return
  101. }
  102. err = q.Append(message)
  103. if err != nil {
  104. return
  105. }
  106. iotMap.MapMeterCalc.Add(elMeter.Id, calc)
  107. }
  108. func packHj212(d *iotStruct.CollectData, cfg *iotStruct.ReportConfig) (string, bool) {
  109. now := time.Now()
  110. nt := fmt.Sprintf("%04d%02d%02d%02d%02d00", now.Year(), now.Month(), now.Day(), now.Hour(), now.Minute())
  111. body := fmt.Sprintf("%s=%s", cfg.GetBmYzKey("p"), getBmYzFloatValue(d.P)) +
  112. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("pa"), getBmYzFloatValue(d.Pa)) +
  113. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("pb"), getBmYzFloatValue(d.Pb)) +
  114. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("pc"), getBmYzFloatValue(d.Pc)) +
  115. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("q"), getBmYzFloatValue(d.Q)) +
  116. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("qa"), getBmYzFloatValue(d.Qa)) +
  117. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("qb"), getBmYzFloatValue(d.Qb)) +
  118. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("qc"), getBmYzFloatValue(d.Qc)) +
  119. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("pf"), getBmYzFloatValue(d.Pf)) +
  120. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("pfa"), getBmYzFloatValue(d.Pfa)) +
  121. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("pfb"), getBmYzFloatValue(d.Pfb)) +
  122. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("pfc"), getBmYzFloatValue(d.Pfc)) +
  123. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("ia"), getBmYzFloatValue(d.Ia)) +
  124. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("ib"), getBmYzFloatValue(d.Ib)) +
  125. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("ic"), getBmYzFloatValue(d.Ic)) +
  126. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("iz"), getBmYzFloatValue(d.Iz)) +
  127. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("ua"), getBmYzFloatValue(d.Ua)) +
  128. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("ub"), getBmYzFloatValue(d.Ub)) +
  129. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("uc"), getBmYzFloatValue(d.Uc)) +
  130. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("uab"), getBmYzFloatValue(d.Uab)) +
  131. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("ubc"), getBmYzFloatValue(d.Ubc)) +
  132. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("uca"), getBmYzFloatValue(d.Uca)) +
  133. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("dp"), getBmYzFloatValue(d.Dp)) +
  134. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("pv"), getBmYzFloatValue(d.Pv)) +
  135. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("f"), getBmYzFloatValue(d.Freq)) +
  136. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("fw"), getBmYzFloatValue(d.Fw)) +
  137. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("tps"), getBmYzFloatValue(d.Tps)) +
  138. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("tqs"), getBmYzFloatValue(d.Tqs)) +
  139. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("fps"), getBmYzFloatValue(d.Fps)) +
  140. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("fqs"), getBmYzFloatValue(d.Fqs)) +
  141. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("tpe"), getBmYzFloatValue(d.Tpe)) +
  142. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("tqe"), getBmYzFloatValue(d.Tqe)) +
  143. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("fpe"), getBmYzFloatValue(d.Fpe)) +
  144. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("fqe"), getBmYzFloatValue(d.Fqe)) +
  145. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("uaw"), getBmYzFloatValue(d.Uaw)) +
  146. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("ubw"), getBmYzFloatValue(d.Ubw)) +
  147. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("ucw"), getBmYzFloatValue(d.Ucw)) +
  148. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("uabw"), getBmYzFloatValue(d.Uabw)) +
  149. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("ubcw"), getBmYzFloatValue(d.Ubcw)) +
  150. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("ucaw"), getBmYzFloatValue(d.Ucaw)) +
  151. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("inbalance"), getBmYzFloatValue(d.IUnbalance)) +
  152. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("unbalance"), getBmYzFloatValue(d.UUnbalance)) +
  153. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("t"), getBmYzFloatValue(d.TemperatureA)) +
  154. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("t2"), getBmYzFloatValue(d.TemperatureB)) +
  155. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("t3"), getBmYzFloatValue(d.TemperatureC)) +
  156. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("t4"), getBmYzFloatValue(d.TemperatureZ)) +
  157. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("hua"), packYcHj212Hx(d.Hua, d.HarUa, d.BaseUa, "baseu")) +
  158. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("hub"), packYcHj212Hx(d.Hub, d.HarUb, d.BaseUb, "baseu")) +
  159. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("huc"), packYcHj212Hx(d.Huc, d.HarUc, d.BaseUc, "baseu")) +
  160. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("hia"), packYcHj212Hx(d.Hia, d.HarIa, d.BaseIa, "basei")) +
  161. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("hib"), packYcHj212Hx(d.Hib, d.HarIb, d.BaseIb, "basei")) +
  162. fmt.Sprintf("&%s=%s", cfg.GetBmYzKey("hic"), packYcHj212Hx(d.Hic, d.HarIc, d.BaseIc, "basei"))
  163. str := fmt.Sprintf("st=%s;cn=4;datatime=%s;cphh=&&tid=%s&%s&", cfg.ST, nt, cfg.MN, body)
  164. crc16 := utils.CalCRC16HJ212([]byte(str))
  165. str1 := fmt.Sprintf("##00%04d", len(str)) + str + fmt.Sprintf("%04X", crc16) + "\r\n"
  166. return str1, true
  167. }
  168. func packYcHj212Hx(val [15]float32, hall, base float32, baseStr string) string {
  169. ret := ""
  170. for i, v := range val {
  171. ret += fmt.Sprintf("h%d:%s,", i*2+1, getBmYzFloatValue(v))
  172. }
  173. ret += fmt.Sprintf("hall:%s,%s:%s", getBmYzFloatValue(hall), baseStr, getBmYzFloatValue(base))
  174. return ret
  175. }
  176. func getBmYzFloatValue(value float32) string {